Siemens 6ES7155-6AU01-0BN0 SIMATIC ET 200SP IM 155-6 PN Standard is the PROFINET interface module used at the head of a SIMATIC ET 200SP distributed I/O station. It connects the installed ET 200SP I/O modules to a Siemens PLC or other PROFINET controller and manages communications for the remote I/O node.
This listing is for the exact Siemens article number 6ES7155-6AU01-0BN0. Siemens identifies this version as the IM 155-6PN Standard, supporting up to 32 ET 200SP I/O modules and up to 16 ET 200AL modules. Siemens has announced product phase-out for this revision and identifies 6ES7155-6AU02-0BN0 as the successor.
Key product details
Why this part is especially relevant for MRO: When an interface module fails, the entire remote I/O station can disappear from the control system. Plants supporting validated or long-lived ET 200SP equipment may prefer the exact AU01 revision to minimize engineering changes, while the AU02 successor may be appropriate for a planned update.
Before replacing or migrating, verify TIA Portal hardware configuration, firmware support, PROFINET device name and network settings, attached I/O count, ET 200AL expansion, hot-swap requirements, and machine validation needs.
Need Siemens 6ES7155-6AU01-0BN0? Corwin Solutions can quote the exact phased-out revision, the current successor, or both as clearly separated options. Send the quantity, required condition, and delivery deadline.
Siemens 6ES7155-6AU01-0BN0 SIMATIC ET 200SP IM 155-6 PN Standard is the PROFINET interface module used at the head of a SIMATIC ET 200SP distributed I/O station. It connects the installed ET 200SP I/O modules to a Siemens PLC or other PROFINET controller and manages communications for the remote I/O node.
This listing is for the exact Siemens article number 6ES7155-6AU01-0BN0. Siemens identifies this version as the IM 155-6PN Standard, supporting up to 32 ET 200SP I/O modules and up to 16 ET 200AL modules. Siemens has announced product phase-out for this revision and identifies 6ES7155-6AU02-0BN0 as the successor.
Key product details
Why this part is especially relevant for MRO: When an interface module fails, the entire remote I/O station can disappear from the control system. Plants supporting validated or long-lived ET 200SP equipment may prefer the exact AU01 revision to minimize engineering changes, while the AU02 successor may be appropriate for a planned update.
Before replacing or migrating, verify TIA Portal hardware configuration, firmware support, PROFINET device name and network settings, attached I/O count, ET 200AL expansion, hot-swap requirements, and machine validation needs.
Need Siemens 6ES7155-6AU01-0BN0? Corwin Solutions can quote the exact phased-out revision, the current successor, or both as clearly separated options. Send the quantity, required condition, and delivery deadline.