Beckhoff KL4002 Bus Terminal 2-Channel 0-10V Analog Output 12-Bit

$0.00

Beckhoff KL4002 is a two-channel 0 to 10 V analog output Bus Terminal used in industrial automation, machine maintenance, exact-part replacement, and installed-base support.

The Beckhoff KL4002 generates two standard 0 to 10 V analog output signals for industrial equipment connected to a Beckhoff K-bus system. The terminal converts digital process values from the controller into isolated analog voltages that can be used to command proportional valves, speed references, analog setpoints, laboratory devices, or other equipment with a 0 to 10 V input. Both channels share a common ground potential and are packaged in Beckhoff's compact Bus Terminal housing.

This page is built around the exact manufacturer reference KL4002. Industrial components that look similar can differ in firmware, voltage, signal type, I/O architecture, connector style, communications, safety functions, or machine-specific configuration. Using the exact part number helps reduce engineering changes, troubleshooting, and production downtime.

Lifecycle / sourcing status

Regular delivery, mature K-bus product with broad installed-base replacement demand.

Key product details

  • Product family: Beckhoff KL4xxx analog output Bus Terminals
  • Outputs: 2
  • Signal range: 0 to 10 V
  • Resolution: 12 bit
  • Load: >5 kΩ
  • Output protection: Short-circuit proof
  • Output error: < ±0.1% of end value
  • Conversion time: Approx. 1.5 ms
  • Electrical isolation: 500 V between K-bus and signal voltage
  • Power supply: Via K-bus

Common applications

Proportional valves, analog speed commands, machine actuators, process setpoints, laboratory systems, OEM machinery, test equipment, and mature Beckhoff K-bus control systems.

Compatibility and ordering note: Verify KL4002 model, 0-10 V signal range, connected load, K-bus coupler/controller, common-ground arrangement, process-data mapping, terminal revision, and machine software before replacement.

Why this part is commonly sourced: Exact KL4002 sourcing is valuable because mature machines may rely on its specific output range, mapping, electrical characteristics, and K-bus architecture. Replacing the whole I/O platform only because one analog terminal failed can be unnecessarily expensive.

Need KL4002? Corwin Solutions helps industrial buyers, maintenance teams, OEMs, integrators, and machine builders locate exact automation and MRO components, including current, legacy, obsolete, and discontinued parts. Availability, condition, exact configuration, pricing, and lead time are confirmed at quotation.

Beckhoff KL4002 is a two-channel 0 to 10 V analog output Bus Terminal used in industrial automation, machine maintenance, exact-part replacement, and installed-base support.

The Beckhoff KL4002 generates two standard 0 to 10 V analog output signals for industrial equipment connected to a Beckhoff K-bus system. The terminal converts digital process values from the controller into isolated analog voltages that can be used to command proportional valves, speed references, analog setpoints, laboratory devices, or other equipment with a 0 to 10 V input. Both channels share a common ground potential and are packaged in Beckhoff's compact Bus Terminal housing.

This page is built around the exact manufacturer reference KL4002. Industrial components that look similar can differ in firmware, voltage, signal type, I/O architecture, connector style, communications, safety functions, or machine-specific configuration. Using the exact part number helps reduce engineering changes, troubleshooting, and production downtime.

Lifecycle / sourcing status

Regular delivery, mature K-bus product with broad installed-base replacement demand.

Key product details

  • Product family: Beckhoff KL4xxx analog output Bus Terminals
  • Outputs: 2
  • Signal range: 0 to 10 V
  • Resolution: 12 bit
  • Load: >5 kΩ
  • Output protection: Short-circuit proof
  • Output error: < ±0.1% of end value
  • Conversion time: Approx. 1.5 ms
  • Electrical isolation: 500 V between K-bus and signal voltage
  • Power supply: Via K-bus

Common applications

Proportional valves, analog speed commands, machine actuators, process setpoints, laboratory systems, OEM machinery, test equipment, and mature Beckhoff K-bus control systems.

Compatibility and ordering note: Verify KL4002 model, 0-10 V signal range, connected load, K-bus coupler/controller, common-ground arrangement, process-data mapping, terminal revision, and machine software before replacement.

Why this part is commonly sourced: Exact KL4002 sourcing is valuable because mature machines may rely on its specific output range, mapping, electrical characteristics, and K-bus architecture. Replacing the whole I/O platform only because one analog terminal failed can be unnecessarily expensive.

Need KL4002? Corwin Solutions helps industrial buyers, maintenance teams, OEMs, integrators, and machine builders locate exact automation and MRO components, including current, legacy, obsolete, and discontinued parts. Availability, condition, exact configuration, pricing, and lead time are confirmed at quotation.